Abstract

A nationwide survey of Australian homes was conducted to determine the average annual dose equivalents to the Australian population from exposure to Rn and gamma radiation. The exposure to Rn was measured using solid-state track detectors (SSTD), while the gamma radiation dose was concurrently determined using thermoluminescent dosimetry. Dosimeters were placed in approximately 3,400 randomly distributed homes (representing about 1 in 1,400 occupied dwellings) for 12 mo. The average Rn concentration in Australian homes measured over a year is 11 Bq m-3. Using appropriate conversion factors, the annual average effective dose equivalents to the Australian population were determined to be 0.5 mSv and 0.9 mSv for Rn and gamma radiation exposure, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.