In the Defense Waste Processing Facility (DWPF) of Savannah River Plant site waste will be immobilized in borosilicate glass. A knowledge of the neutron emission from DWPF glass is necessary to assess shielding requirements for the DWPF canister and to determine the response characteristics of the Neutron Transmission Glass Level Detection System. Excellent agreement was obtained between measured and calculated neutron emissions (yields) from Pu spiked black frit glasses using West's method of weighting components based on relative stopping power. The calculated values for the three glasses were 2-7 percent higher than measured. Calculations using a Nj Zj weighting method were 19-22 percent lower than measured. The good agreement between measurement and calculation using West's method lends confidence in its use to calculate the neutron source term for DWPF glass.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.