Abstract

This study aims to validate radioactive seed localization (RSL) as an alternative to wire localization (WL) in the operative excision of nonpalpable breast lesions. Eligible patients were recruited sequentially. A sample of 99 patients treated with WL was compared to the next 383 patients treated with RSL. Margins were considered "negative" if > or =2 mm from in-situ and invasive disease. Pain and convenience scores were recorded on a 10-point scale. Patient characteristics and histology were similar. The lesion and localization device were retrieved in all patients. Margins of the first specimen were negative in 73% of RSL patients, versus 54% of WL patients (p < 0.001). A second operation was required in 8% of RSL patients to achieve negative margins, versus 25% of WL patients (p < 0.001). Pain scores were not statistically different. However, the RSL group had higher convenience scores (p = 0.015). RSL is safe, effective, and compared to WL, reduces the rates of intraoperative re-excision and reoperation for positive margins by 68%. Patient satisfaction is improved with RSL. We strongly favor RSL over WL.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.