Abstract
A fifth and seventh order harmonic elimination scheme for IM drive with a multilevel dodecagonal voltage space vector structure using a single DC source is proposed in this work. Single DC source requirement makes four quadrant operation of the drive system simpler compared to the multilevel do-decagonal structures presented in literatures before. The space vector structure consists of six concentric dodecagons, combining the advantages of multilevel operation as well as dodecagonal structure. The topology consists of a three-level flying capacitor (FC) inverter cascaded with a capacitor fed H-bridge (CHB) inverter. The FC inverter operating at high voltage switches in a quasi-square wave mode whereas the CHB inverter operating at a lower voltage switches at high frequency to remove the harmonics generated by the FC inverter. Switching losses are low, both in the FC and CHB inverters. Experiment results for open-loop V/f operation are included in this paper showing the effectiveness of the drive scheme.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.