Abstract
The aim of this quality improvement (QI) initiative was, first, to examine the impact of a standardized handover process between the OR and the ICU on process and information-sharing errors, and second, to examine provider satisfaction with the handover process. We conducted prospective observations of the handover process before and after implementation of the QI initiative. In the pre-process improvement period, 38 cardiothoracic patients were observed during handover. In the post-process improvement period, 38 patients were observed after implementation of the newly developed, standardized handover process and communication template. Provider satisfaction surveys were distributed at each observation during the pre- and post-process improvement periods. Compared with the pre-process improvement period, there was a significant decrease in interruptions during report in the post-process improvement period (1.7 ± 1.1 to 0.13 ± 0.34). There were also significantly fewer handover process errors (6.1 ± 2.8 to 1.7 ± 1.5), and fewer information-sharing errors (5.2 ± 2.7 to 2.3 ± 1.5). Average report time increased slightly, from 13.2 ± 6.8 minutes to 14.6 ± 3.8 minutes, but the increase was not significant. A total of 211 provider satisfaction surveys were completed in the pre-process improvement period and 95 in the post-process improvement period. Providers in all disciplines completed surveys in both time periods, and there was no significant difference in the percentage of respondents from any discipline. Responses to the following survey items showed significant improvement in the post-process improvement period: surgery report was satisfactory, anesthesia report was satisfactory, could hear all the report, pre-op anesthesia information was helpful, and start and end of handover were clear. Post-process improvement as well, more respondents disagreed that the person handing off the patient was under time pressure and that the person taking on responsibility for the patient was under time pressure. A standardized OR-ICU handover process developed by a multidisciplinary team decreased handover process and information-sharing errors and increased provider satisfaction, with no significant increase in handover time.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.