Abstract

We conducted an observational prospective multicenter study to describe the practices of mechanical ventilation, to determine the incidence of use of large intra-operative tidal volumes (≥10 ml.kg(-1) of ideal body weight) and to identify patient factors associated with this practice. Of the 2960 patients studied in 97 anaesthesia units from 49 hospitals, volume controlled mode was the most commonly used (85%). The mean (SD) tidal volume was 533 (82) ml; 7.7 (1.3) ml.kg(-1) (actual weight) and 8.8 (1.4) ml.kg(-1) (ideal body weight)). The lungs of 381 (18%) patients were ventilated with a tidal volume>10 ml.kg(-1) ideal body weight. Being female (OR 5.58 (95% CI 4.20-7.43)) and by logistic regression, underweight (OR 0.06 (95% CI 0.01-0.45)), overweight (OR 1.98 (95% CI 1.49-2.65)), obese (OR 5.02 (95% CI 3.51-7.16)), severely obese (OR 10.12 (95% CI 5.79-17.68)) and morbidly obese (OR 14.49 (95% CI 6.99-30.03)) were the significant (p ≤ 0.005) independent factors for the use of large tidal volumes during anaesthesia.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.