Abstract

BackgroundThe Auditory brainstem implant (ABI) is a new surgical option for hearing impaired children. Intraoperative neurophysiology monitoring includes brainstem mapping of cranial nerve (CN) IX, X, XI, XII and their motor nuclei, and corticobulbar tract motor-evoked potential. These require laryngeal electrodes and intra-oral pins, posing a challenge to airway management especially in the pediatric airway, where specialized electromyogram (EMG) tracheal tubes are not available.Challenges include determining the optimum position on the endotracheal tube (ETT) in which to place laryngeal electrode, and the increase in external diameter of ETT contributed by the wrapping the electrode around the shaft of ETT; this may necessitate downsizing of the tracheal tube. An appropriate size ETT minimizes displacement, which in turn can affect electrode contact with the vocal cords. Finally, a small thus crowded pediatric airway makes for difficult visualization during placement of intraoral neuromonitoring electrodes. The use of a videolaryngoscope helps determine optimum electrode placement.Case presentationWe describe intraoperative neurophysiology monitoring and airway management for the first two ABI procedures in Singapore, conducted for children with congenitally absent cochlear nerves.ConclusionNeurophysiology cranial nerve IX, X, XII monitoring in the ABI procedure requires intraoral placement of electrodes. Care should be exercised during placement and removal. Vagus nerve monitoring in children requires attention to tube preparation, and consideration should be given to avoidance of airway topicalization.

Highlights

  • The Auditory brainstem implant (ABI) is a new surgical option for hearing impaired children

  • Neurophysiology cranial nerve IX, X, XII monitoring in the ABI procedure requires intraoral placement of electrodes

  • Care should be exercised during placement and removal

Read more

Summary

Conclusion

Neurophysiology cranial nerve IX, X, XII monitoring in the ABI procedure requires intraoral placement of electrodes. Care should be exercised during placement and removal. Vagus nerve monitoring in children requires attention to tube preparation, and consideration should be given to avoidance of airway topicalization

Background
Discussion and conclusions
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.