Abstract
A new quantitative method for the enumeration of Legionella bacteria in water is described. Appropriate tenfold serial dilutions of water samples concentrated by membrane filtration are plated in triplicate on buffered charcoal yeast extract agar. After incubation for 3 days representative smears from individual plates are tested for the presence of Legionella by direct fluorescent antibody staining. The number of positive plates in each dilution is used to calculate the Legionella count by means of conventional most probable number statistics. In comparative tests on a variety of water samples this method yielded significantly higher counts than previously used procedures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.