Abstract

Fracture toughness K JIc values, determined on standard compact specimens by the use of modified equations of Rice, Paris and Merkle, and Merkle and Corten, are presented. The equations permit elimination of errors caused by inaccuracies in the loadline displacement measurements, and they can be applied not only for deeply cracked specimens but also for a wider range of ratios a W . Experimental results, obtained on two low strength steels using 75 and 40mm thick specimens, showed a very good agreement between the K JIc values calculated by both equations. These values do not differ by more than 2%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.