Abstract

Energy accommodation coefficient (EAC), used in thermal boundary condition in micro gas flow and heat transfer, is reported to be always less than unity and greatly influenced by the wall characters. According to EAC’s definition, the statistical algorithm was described and EAC for argon gas was studied by two dimensional NEMD simulations with heat conduction between two smooth platinum plates at different temperatures. With one wall’s temperature fixed, the non-equilibrium EACs were calculated by changing the other wall’s temperature. Meanwhile, the equilibrium EAC at one temperature can be extrapolated from a series of non-equilibrium EACs as the temperature difference approaches to zero. The effects of wall temperature, wall temperature difference, and Kn on EAC were investigated. Non-equilibrium EAC increases with wall temperature difference decreased, and becomes larger with increased Kn. And equilibrium EAC is larger for lower temperature and larger Kn.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.