The Hole Erosion Test (HET) is used to determine a critical value of hydraulic shear stress, and hence erodibility, of a compacted soil specimen with a preformed axial hole. A modification to the HET is described, termed the HET-P, in which a Pitot-static tube is introduced at the outlet of the preformed hole. Tests are reported on three specimens of non-erodible PVC with a 6 mm, 12 mm, or 24 mm diameter hole, respectively. Measurements of total energy head and flow velocity of the exiting jet are obtained with the Pitot-static tube, and correlated with mean flow velocity in the hole. HET-P data obtained for non-erodible specimens show the value of hydraulic gradient deduced from measurement of hydraulic head at the sidewall of the standard HET device overestimates, significantly, the hydraulic shear stress on the boundary of the preformed hole. The error varies with size of the hole diameter, and is found to be as much as one order of magnitude.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.