Abstract

The double loop electrochemical potentiodynamic reactivation technique was developed to detect sensitization in wrought stainless steel. Because cast stainless steel has a different microstructure than wrought stainless steel, neither the double loop nor the single loop EPR technique has the selectivity required to detect sensitization. By using a modified double loop EPR technique in which the peak potential is raised to 450 mV vs. SCE, the sweep rate is slowed to 3 V/h, and the concentration is increased to 0.02M, sensitization can be detected in cast stainless steel.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.