Abstract

A modified curve-approximated hysteretic model for partially concrete-filled steel tube (PCFST) bridge piers is developed based on the previous research work. The proposed model, which consists of a series of quadratic and cubic curves and takes into account the P-Δ effect, pinching behavior in unloading-reloading hysteretic loops, and deterioration of strength and stiffness, can be used to precisely describe complicated hysteretic behavior of cantilever-type PCFST bridge piers. Parameters of this model are calibrated on the basis of quasi-static cyclic test results. To verify the validity of the proposed model, a total of 12 pseudo-dynamic tests were carried out. The detailed comparisons of different seismic performance indices between experimental and numerical results, such as the maximum response displacement, the residual displacement, and the amount of energy dissipation, indicated that the proposed model can be an acceptable complementary and assisting tool for the nonlinear seismic response assessment of PCFST piers.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.