This paper addresses the problem of Oscillatory Failure Cases (OFC) detection in the Electrical Flight Control System (EFCS) of the Airbus airplanes. OFC can lead to strong interactions with loads and aero-elasticity and consequently are to be detected very early in time. The work describes the status of on going research activity undertaken within a collaborative project between Bordeaux University (France) and Airbus. An hydraulic actuator model is currently used as the basis for a robust analytical redundancy-based technique implemented in A380 Flight Control Computer (FCC) for detecting unauthorized oscillatory events. For upcoming and future generation aircraft (A/C), it could be required to detect OFC earlier with less important amplitude. The method presented here is based on nonlinear state space modeling, associated with the same decision test as used by in-service Airbus A/C. It is shown that the model quality could be improved significantly by reliable estimating of some physical parameters. The fault indicating signals are compared on data set obtained from A380 computers during flight tests.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.