Abstract

AbstractIn a medical procedure to comminute kidney stones the patient is subjected to hypersonic waves focused at the stone. Unfortunately such shock waves also damage the surrounding kidney tissue. We present here a model for the mechanical response of the soft tissue to such a high speed loading regime.The material model combines shear induced plasticity with irreversible volumetric expansion as induced, e.g., by cavitating bubbles. The theory is based on a multiplicative decomposition of the deformation gradient and on an internal variable formulation of continuum thermodynamics. By the use of logarithmic and exponential mappings the stress update algorithms are extended from small‐strain to the finite deformation range. In that way the time‐discretized version of the porous‐viscoplastic constitutive updates is described in a fully variational manner.By numerical experiments we study the shock‐wave propagation into the tissue and analyze the resulting stress states. A first finite element simulation shows localized damage in the human kidney. (© 2004 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.