Abstract

Theoretical model for calculating the outlet flue gas temperature of limestone-gypsum wet flue gas desulfurization (FGD) absorption tower is important for water consumption calculation. In this paper, the energy balance in the spray zone is analyzed and a model for calculating the outlet flue gas temperature of FGD absorption tower is proposed. An example computation of the outlet flue gas temperature of a typical 600MW class unit’s operation data is introduced, the result has verified the model. A further study of significance analysis has then been made to analyze and simplify the model.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.