Abstract

The accuracy of the single-breath CO2 inhalation test as a method for determining peripheral chemoreflex gain (Gp) is evaluated through computer simulations using a mathematical model of the closed-loop respiratory control system. Estimates of Gp (G'p) are based on "corrected" changes in end-tidal PCO2, because the uncorrected end-tidal values do not accurately reflect changes in alveolar PCO2. The influence of the central chemoreflex on G'p is generally less than 10% but can become disproportionally more significant as the relative contribution of the peripheral chemoreflex diminishes. G'p tends to overestimate Gp with the inclusion of peripheral chemoreceptor rate sensitivity, but this effect is offset by the time constant for adaptation. The spontaneous variability of breathing can seriously impair the resolution of G'p. Averaging of G'p deduced from individual single-breath tests can lead to erroneous estimates of Gp even when a large number of repetitions are performed. This problem can be minimized by first ensemble averaging the data from individual single-breath tests and, then, computing G'p from the resulting mean changes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.