Abstract

This article presents a wireless neural implant with body-coupled (BC) data transmission and power delivery for freely behaving animals and incorporates a precision front end for high-quality neural recordings. The neural implant utilizes the body as a wireless transmission medium where it only needs small electrodes for data transmission and power delivery. An external device with patch electrodes can then be placed far away from the implant without the need for precise alignment. Furthermore, a four-channel continuous-time delta–sigma modulator (CT- <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Delta \Sigma \text{M}$ </tex-math></inline-formula> ) is integrated into the system for precision neural recordings. Each neural recording CT- <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Delta \Sigma \text{M}$ </tex-math></inline-formula> achieves an 82.3-dB signal-to-noise and distortion ratio (SNDR) and an 83.3-dB dynamic range (DR) while consuming only 8.6- <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\mu \text{W}$ </tex-math></inline-formula> at a signal bandwidth of 10 kHz. The neural implant integrated circuit (IC) is fabricated in a 0.11- <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\mu \text{m}$ </tex-math></inline-formula> CMOS with a high-density capacitor option, and the BC data receiver (RX) IC is implemented in a 0.18- <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\mu \text{m}$ </tex-math></inline-formula> CMOS. The implant IC occupies a chip area of 4 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\text {mm}^{2}$ </tex-math></inline-formula> , including a 5-nF on-chip capacitor, and draws 280 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\mu \text{A}$ </tex-math></inline-formula> from a 2.3-V supply with a working data transmitter (TX) electrode. By exploiting direct-digital signaling for data transmission, the neural implant achieves a data rate of 20.48 Mb/s and a wireless power recovery of 644 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\mu \text{W}$ </tex-math></inline-formula> , resulting in an energy efficiency of 32 pJ/b. The entire neural implant system has been successfully verified by both electrical and in vivo measurements, while the wirelessly recorded electrocorticography (ECoG) signals with the prototype neural implant inside a rat demonstrate the end-to-end functionality of the proposed system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.