Abstract

We present a miniaturized, free-floating monitoring system which makes use of electron transfer in Shewanella oneidensis sequestered behind a permeable membrane while maintaining diffusive contact with the environment, allowing for sensing environmental conditions. The system makes use of a commercial off-the-shelf (COTS) integrated circuit (IC) which sets a potential between a working electrode and a Ag/AgCl reference electrode while recording the resulting current from the electroactive cells. We successfully sensed both pyruvate and the environmental presence of E. coli via changes in the currents sensed. This work will enable the development of mobile aquatic sensing systems which make use of bacterial electron transfer as a transduction method. Further miniaturization of the recording mote, electrodes, packaging, and system is discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.