Abstract

A noninvasive technique for studying blood flow dynamics in human skin capillaries is described. A light microscope combined with a closed-circuit TV system was used to monitor and record capillary blood flow velocity on video tape. Arterial pulsations were recorded plethysmographically and converted into video signals by modulating the position of a square, white area in the televised scene. Twelve healthy subjects were studied. The mean (+/- SD) resting capillary blood flow velocity was 0.65 +/- 0.3 mm/s at an average skin temperature of 30.4 +/- 2.3 degrees C. Spontaneous fluctuations at a frequency of 6-10 cycles/min were observed in most subjects. A well-pronounced flow pulsatile component could be demonstrated in all capillaries studied. The technique can be used in clinical practice for studying the physiology and pathophysiology of cutaneous microcirculation in man. It can be expected that the method may become an important diagnostic tool in diseases that involve disturbances of the microcirculation, such as diabetes, hypertension, and atherosclerosis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.