Abstract

Ferric iron constituting approximately 0.01% — 0.1% may be determined by a heterometric titration with α-nitroso-β-naphthol. The solution may contain 99.9% or more of calcium, barium, magnesium, aluminium, chromium, manganese, nickel, cadmium or lead salts. No previous separation is necessary. The α-nitroso-β-naphthol is dissolved in alcohol. The analysed solution must be acidified. No complexing agents are necessary. Citrate or tartrate must be absent. The maximum optical density values which are obtained at the end of the titration are proportional to the amount of iron which is analysed. These maximum values are entirely unaffected by the concentrated salt solutions. The heterometric sensitivity of the reaction between iron and α-nitroso-β-naphthol is three times higher in 50% alcoholic solution than in water. The titration takes about one hour. The error is 0.0—4%.