Abstract

ObjectiveTo evaluate the shaping ability of three thermally-treated rotary nickel-titanium (NiTi) systems including ProTaper Next (PTN), HyFlex™ CM (HFCM) and HyFlex™ EDM (HFEDM) during root canal preparation in simulated root canals.MethodsA total of 45 simulated root canals were divided into three groups (n = 15) and prepared with PTN, HFCM or HFEDM files up to size 25. Microcomputed tomography (microCT) was used to scan the specimens before and after instrumentation. Volume and diameter changes, transportations and centring ratios at 11 levels of the simulated root canals were measured and compared.ResultsHFEDM caused significantly greater volume increases than HFCM and PTN in the entire root canal and in the apical and middle thirds. HFCM removed the least amount of resin in the coronal third compared with HFEDM and PTN. Overall, HFCM caused significantly less transportation in the apical 2 mm and was better centred than PTN in the apical 3 mm.ConclusionUnder the conditions of this study, all systems prepared curved canals without significant shaping errors and instrument fracture. PTN and HFCM cut less resin than HFEDM. HFCM stayed centred apically and cut the least material coronally.