Abstract
In a recent prevalidation study, the use of a methylcellulose colony-forming unit-granulocyte/macrophage (CFU-GM) macroassay for two independent in vitro tests (human and murine cell based) was suggested for quantifying the potential haematotoxicity of xenobiotics. In this paper, we describe the transfer of the macroassay to a 96-well plate microassay, in which the linearity of the response was studied (both in terms of CFU-GM and optical density [OD] versus the number of cells cultured), and the inhibitory concentration (IC) values for doxorubicin, 5-fluorouracil and taxol were determined and compared with those obtained by using the original macroassay. Fresh murine bone marrow and human umbilical cord blood mononuclear cells were used as a source of myeloid progenitors. The cells were cultured in methylcellulose containing granulocyte/macrophage-colony-stimulating factor, and in the presence of increasing drug concentrations. The cloning capacity of the progenitors was measured both as the number of colonies counted manually (CFU-GM), and as OD evaluated with an automated plate reader in an MTT test. Our results show that, in the microassay, up to 20 colonies/well could be easily counted, and that this range (20 to zero) gave a regression line from which IC values were calculated, which were very close to those obtained by using the macroassay (where the range of colony numbers was from 100 to zero). The test did not give good results when the OD (instead of the colony count) was used as the endpoint, because, although a high coefficient of determination was obtained, the OD values ranged from 0.6 to zero and the IC values determined were not comparable to those obtained by manual counts. The use of the microassay dramatically reduces the quantity of methylcellulose needed, and permits hundreds of cultures to be processed in the same experiment, contributing to significant reductions in both the work involved and the cost. A further important benefit is a reduction of the amount of drug needed for testing, which is crucial for screening new molecules, when many different toxicological tests have to be carried out. The microassay is therefore a useful and reproducible tool for screening compounds (chemicals, drugs and xenobiotics) for potential haematotoxicity directly on human myeloid progenitors, and could contribute significantly to reducing the use of animals in toxicity testing.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.