A methodology for analysing non-homogeneous sets of experimental data for a selected phenomenon from separate effect test facilities and integral test facilities is presented in this paper. The critical heat flux from the validation matrices was chosen as the phenomenon to be studied; the results obtained in three test facilities are analysed. The method presented is applied for estimating the accuracy with which a thermal-hydraulic transient code can predict the critical heat flux in an actual nuclear power plant.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.