Abstract

To develop a method to estimate the mean fractional volume of fat (ν¯fat) within a region of interest (ROI) of a tissue sample for wide-angle x-ray scatter (WAXS) applications. A scatter signal from the ROI was obtained and use of ν¯fat in a WAXS fat subtraction model provided a way to estimate the differential linear scattering coefficient μs of the remaining fatless tissue. The efficacy of the method was tested using animal tissue from a local butcher shop. Formalin fixed samples, 5 mm in diameter 4 mm thick, were prepared. The two main tissue types were fat and meat (fibrous). Pure as well as composite samples consisting of a mixture of the two tissue types were analyzed. For the latter samples, νfat for the tissue columns of interest were extracted from corresponding pixels in CCD digital x-ray images using a calibration curve. The means ν¯fat were then calculated for use in a WAXS fat subtraction model. For the WAXS measurements, the samples were interrogated with a 2.7 mm diameter 50 kV beam and the 6° scattered photons were detected with a CdTe detector subtending a solid angle of 7.75 × 10(-5) sr. Using the scatter spectrum, an estimate of the incident spectrum, and a scatter model, μs was determined for the tissue in the ROI. For the composite samples, a WAXS fat subtraction model was used to estimate the μs of the fibrous tissue in the ROI. This signal was compared to μs of fibrous tissue obtained using a pure fibrous sample. For chicken and beef composites, ν¯fat=0.33±0.05 and 0.32 ± 0.05, respectively. The subtractions of these fat components from the WAXS composite signals provided estimates of μs for chicken and beef fibrous tissue. The differences between the estimates and μs of fibrous obtained with a pure sample were calculated as a function of the momentum transfer x. A t-test showed that the mean of the differences did not vary from zero in a statistically significant way thereby validating the methods. The methodology to estimate ν¯fat in a ROI of a tissue sample via CCD x-ray imaging was quantitatively accurate. The WAXS fat subtraction model allowed μs of fibrous tissue to be obtained from a ROI which had some fat. The fat estimation method coupled with the WAXS models can be used to compare μs coefficients of fibroglandular and cancerous breast tissue.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.