Abstract

We put forward a method of rapid preparation of chloride selective electrode (Ag/AgCl electrode) by dipping silver wire into sodium hypochlorite solution. The electrodes were prepared through different immersion time. The properties of the electrodes, such as Nernst response, response time and long-term stability, were tested in simulated concrete pore solutions (SCPS). Moreover, the surface morphology of the electrodes was also detected after immersion in solutions over three months. The experimental results reveal that the Ag/AgCl electrode with the fabrication time of 20 minutes (E-20) which is recommended to work as the chloride ion selective electrode has the best performance. Compared to that fabricated by the electrolytic process (E-EP), E-20 can be manufactured in mass. The method has almost the same good performance of Nernst response as E-EP, and has a better response time which is less than 25 seconds. The method also shows a better good long-term stability in SCPS containing chloride ions over three months.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.