Abstract

After referring briefly to various methods of measuring frequency, the paper describes in detail an instrument designed to give a statistical record of the inaccuracy in the frequency of a.c. mains supply.Records have been made, in the Dollis Hill Research Laboratories of the G.P.O., of the mains-frequency error at various times during 1937–40, and statistical analysis of the results obtained in four test periods shows that the distribution follows very closely the normal-error law. The standard deviation of the corresponding normal-error curve has been calculated for each of the test periods.The purpose for which the recorder was designed was to test the practicability of using a.c. mains supply to drive synchronous motors on teleprinters and multi-frequency generators used in the Post Office telegraph service; the test results are discussed from this standpoint.The reading of the paper was followed by a demonstration by Mr. L. Essen of the principles of the quartz-crystal clock.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.