The complete distribution of high-energy photon primary absorbed dose along the beam path within a semi-infinite or finite water phantom can be expressed by one functional equation. The derivation is based on a technique of convoluting a primary collision kerma distribution function with a pair of forward and backward spread dose-distribution functions. In particular, the characteristic patterns of primary dose in the regions near the beam entrance and exit surfaces can be obtained. The calculated ratio of primary dose to primary collision kerma in the electron-equilibrium region in water for 60Co radiation is 1.0060 and that for 25-MV radiation is 1.0444.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.