We propose a method of a sigle phase PWM for a utility-connected power supply in photovoltaic power generation systems. In this paper, the PWM is derived from camparing levels of signal waves with ones of carrier waves which have bipolar swing different from unipolar one in the conventional PWM, and shifting phase a little at exery on-off time. We can expect that array voltage needed is reduced by about 15% and harmonics content contained in output voltage is reduced by about 24% in this PWM in comparison with the conventional with equal output voltage.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.