Abstract
Fluorescein-isothiocyanate dextran (FITC-dextran; MW approximately 70,000) was used in isolated rat hearts to compare normal vascular perfusion of ventricular myocardium with the pattern and extent of reperfusion following 60 minutes of global ischemia. Its gross distribution in frozen transverse sections through the ventricles was similar to that of sodium fluorescein. However, unlike 0.1% sodium fluorescein, 6.7% FITC-dextran has a viscosity similar to that of blood, and its much higher molecular weight prevents its diffusion beyond the ischemically injured vessels. Furthermore, staining by the alcoholic periodic acid-Schiff technique enabled tracer distribution to be confirmed microscopically and distinguished competent from incompetent vessels in paraffin embedded material.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.