Abstract
In the microchannels made of hydrophobic materials, the fluid velocity is determined by the zeta potential and velocity slip, both of which may be inhomogeneous due to the adsorption of protein to the channel wall. The inhomogeneity of zeta potential and slip coefficient sometimes causes recirculating flows which in turn affect the transport and mixing of solutes through the microchannels. In the present investigation we devise a method for the simultaneous estimation of inhomogeneous zeta potential and inhomogeneous slip coefficient using velocity measurements. A conjugate gradient method supplemented by the adjoint variable method is adopted in the solution of the relevant inverse problem to reduce the computational burden. The present method is found to estimate the inhomogeneous zeta potential and the slip coefficient simultaneously even with noisy velocity measurements. This method is expected to contribute to the optimal design and robust operation of various microfluidic devices, where the flow patterns and the volumetric flow rates are critically influenced by the profiles of inhomogeneous zeta potential and inhomogeneous slip coefficient.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.