Abstract

In view of the settlement problem of transmission tower foundation, the vibration characteristics of transmission towers under wind force are measured experimentally. In this paper, the 110 kV cat head transmission tower of Xi’an Polytechnic University is measured and analyzed. Firstly, the acceleration sensor and meteorological sensor are installed on the tower to collect the vibration response and environment parameters of the tower in real time. Then, an experiment platform is built to simulate the tower settlement, and the vibration response of the tower after settlement is measured in time. Finally, the low-order modal frequencies of the transmission tower before and after settlement under wind force load are extracted by stochastic subspace identification (SSI), and the relationship between modal frequencies of different modes is analyzed via temperature correction. By comparison and analysis, it is obvious that the X-direction modal frequencies before and after settlement under natural wind load are changed, and the change rate increases with the increase of settlement displacement, which can be used as effective evidence for judging the settlement of transmission tower foundation.

Highlights

  • In electrical power systems, the transmission tower is an integral component of power transmission, and its safe operation is an important factor

  • Some scholars have carried out wind tunnel tests on the EHV (Extra-high Voltage) transmission tower line system and studied the dynamic characteristics of the system under different wind speeds [8]

  • Transmission tower settlement is caused by its foundation and underground soil, which is uniform

Read more

Summary

Introduction

The transmission tower is an integral component of power transmission, and its safe operation is an important factor. The settlement tilt of a tower can be caused by severe natural environmental conditions (such as rain, snow, wind and so on) or man-made destruction and other factors, which may even cause the tower collapse. The finite element analysis method has often been used to analyze the dynamic characteristics and stability in wind conditions in the case of the complex structure of the tower [5,6]. Some scholars have conducted nonlinear buckling analysis of the tower line system, determined the critical wind load and analyzed the dynamic characteristics of the tower line system under different wind loads. Some scholars have carried out wind tunnel tests on the EHV (Extra-high Voltage) transmission tower line system and studied the dynamic characteristics of the system under different wind speeds [8].

Methods
Discussion
Conclusion