Abstract
A new method for reducing the harmonics involved in the output voltages of a double-connected inverter is proposed. By adding four auxiliary switching devices and an interphase transformer with a secondary winding to the conventional 12-step inverter, output voltages of the proposed circuit can produce almost the same waveforms as a conventional 36-step inverter. In this paper, circuit performances and output voltage waveforms are discussed, and optimum parameters are derived. The effects on harmonic reductions are then clarified by theoretical and experimental results, and the ratings of system components are investigated. >
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.