Growth in the demand for higher capacity hard disk drives has pushed the requirement for head-media spacing to sub-nanometer levels. The drop in operational clearance makes a head-disk interface more susceptible to potential head-wear and contamination related issues. Such degradation processes are often accompanied by a noticeable shift in the head-disk clearance. Hence monitoring an interface for a spacing change can be helpful in early detection of its imminent failure. In this paper, we present a method to detect the change in head-disk spacing using an embedded contact sensor (ECS). This technique involves the analysis of ECS dynamic response for an interface that is subjected to heater induced spacing modulations. As the head moves closer to the disk surface, the magnitude of the ECS frequency components can be used to determine the ‘characteristic spacing’ which can be used as a metric to detect any physical change for a given interface.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.