Abstract

Measuring the noise generated by a pulsed RF amplifier is not a simple task [1]. One method of making this measurement converts the RF pulse to video with a phase detector and uses a spectrum analyzer to measure the noise between the lines of the pulse spectrum. The measurement includes the combined effects of timing jitter, power-supply modulation, and amplifier noise. An alternate method, described in this note, requires less test equipment by using an RF spectrum analyzer to measure the noise at a point outside the pulse spectrum. This measurement responds only to amplifier noise and is valid if the noise density is the same both inside and outside the pulse spectrum. Since this situation tends to be true of broad-band amplifiers such as TWT's and CFA's, the second method is preferable because of its relative simplicity. This note describes the procedure for measuring pulsed amplifier noise using an RF spectrum analyzer. The test setup and measurement procedure are described, as well as the conversion of the measured spectral-density ratio to an equivalent CW signal-to-noise ratio.