Abstract

Detailed model was proposed in this work for exergy analysis of a real biomass boiler. The model was based on an equilibrium model which uses Gibbs Energy minimization and energy balance to calculate the flue gas composition, the temperature of the furnace and the temperature of the flue gases along the boiler. The exergetic efficiency was calculated by the indirect method, and the exergy destruction in each component of the boiler and each material stream was evaluated. The Gibbs minimization model predicted successfully the complete combustion of the biomass and can be adapted to another thermochemical processes. The exergy analysis results showed that the furnace and the water walls have the higher exergy destruction, accounting for 47% and 30% of the total exergy destruction, respectively. In other parts of the boiler, the exergy destruction was higher in the water and steam flows than in the flue gases, and the results indicate that exergy destruction was higher in streams at lower temperatures. The global exergetic efficiency was 42.47%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.