Abstract

A method for estimating the convective radon transport velocity in soils is developed. The approach under review is based on measurements of the radon concentration in soil air. Mathematical models for describing the convective radon transport velocity are discussed. Data on the convective radon transport velocity in commonly encountered soil types are presented. The results obtained from a 2-month experiment aimed at investigating the effect of the atmospheric condition on the convective radon transport velocity are reported. The soil gas radon concentration at 30– 70 cm depth was measured by means of passive track detectors (Type III-b SSNTDs) with 72– 96 h exposure time.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.