A lateral load carrying system consisting of only shear walls is used generally for structures having 14 storeys or more. It can be seen that the effect of earthquakes in the systems consisting of the shear walls or shear walls-core are very small. For resisting earthquake effects it is proposed to construct shear walls which are perpendicular to each other in plan and having the cross sectional area 1.5% of the building. Unfortunately in this proposal, the effect of number of storeys and the division of shear wall area to the necessary parts is not taken into consideration. In this paper, these factors are considered as, number of storeys, plan area of a storey, earthquake risk zone, material properties and shear wall thickness. The criteria for determination of the dimensions of earthquake shear walls which are suitable for architectural considerations of the building are given. For various storey areas and 10 storeys, the lengths of shear walls which ensure the suggested criteria, having the same length are given in diagrams. It is also shown how to find the length of shear walls under the same conditions if there are more than 10 storeys.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.