Abstract

A procedure has been developed for determination of cadmium (Cd) species in solid waste leachates employing a cation exchange resin (Chelex 100) in a batch-column-batch sequence. The procedure allows for determination of free divalent Cd (Cd 2+), labile Cd complexes, slowly labile Cd complexes and stable Cd complexes. The effects of equilibration time, pH, calcium activity and ratio of sample volume to amount of resin have been examined. The method has been tested on standardized chloride and EDTA solutions containing Cd and on two actual leachates. The Cd species determined in the chloride solutions were in accordance with theoretical calculations of Cd chloride complexes, and Cd in the EDTA solution was identified as stable Cd complexes. The two polluted samples included in the test showed only a small percentage of free divalent Cd and a high degree of labile complexes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.