Abstract

An urban traffic link tunnel (UTLT) typically consists of a looped main tunnel and several adjoining ramp tunnels. This complex network system creates a high level of fire risk and complicates smoke control. A generic design procedure to control the smoke flow in a UTLT with longitudinal forced ventilation is proposed in this paper with the relevant design criteria. The ventilation network in a UTLT is divided into three characterized regions: smoke discharge branches, smoke-prevention branches upstream of the fire and the smoke-prevention branches downstream of the fire. This conceptual division converts the looped ventilation network into a branched one, where a simple, one-dimensional calculation approach can be used to develop an appropriate ventilation system, and to solve the flow rates for the various branches. The ventilation system in a UTLT was determined using this novel design method, and the resultant flow rates for the key branches were compared to the steady-state solutions for a three-dimensional numerical simulation. The results demonstrate that the method proposed in this paper is a valid and efficient design tool for controlling smoke in UTLTs.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.