Abstract

Actuator fault diagnosis is often studied under strong assumptions on available sensors: typically it is assumed that either the sensors are fault-free or there is a sufficient redundancy among the sensors. The purpose of this paper is to propose a new method for actuator fault diagnosis which is robust to sensor distortion. It does not require sensor redundancy to compensate sensor distortion. The essential assumption is that sensor distortions are strictly monotonous. Despite the nonlinear and unknown nature of distortions, such sensors still provide useful information for fault diagnosis. A numerical example is provided to illustrate the efficiency of the proposed method.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.