Abstract
Background and objective: Rule-based methods are commonly used to estimate the arrangement of myocardial fibers by solving the Laplace problem with appropriate Dirichlet boundary conditions. Existing algorithms are using the Finite Element Method (FEM) to solve the Laplace–Dirichlet problem. However, meshless methods are under development for cardiac electrophysiology simulation. The objective of this work is to propose a meshless rule based method for the determination of myocardial fiber arrangement without requiring a mesh discretization as it is required by FEM.Methods: The proposed method employs the Fragile Points Method (FPM) for the solution of the Laplace–Dirichlet problem. FPM uses simple discontinuous trial functions and single-point exact integration for linear trial functions that set it as a promising alternative to the Finite Element Method. We derive the FPM formulation of the Laplace–Dirichlet and we estimate ventricular and atrial fiber arrangements according to rules based on histology findings for four different geometries. The obtained fiber arrangements from FPM are compared with the ones obtained from FEM by calculating the angle between the fiber vector fields of the two methods for three different directions (i.e., longitudinal, sheet, transverse).Results:The fiber arrangements that were generated with FPM were in close agreement with the generated arrangements from FEM for all three directions. The mean angle difference between the FPM and FEM vector fields were lower than 0.030∘ for the ventricular fiber arrangements and lower than 0.036∘ for the atrial fiber arrangements.Discussion:The proposed meshless rule-based method was proven to generate myocardial fiber arrangements with very close agreement with FEM while alleviates the requirement for a mesh of the latter. This is of great value for cardiac electrophysiology solvers that are based on meshless methods since they require a well defined myocardial fiber arrangement to simulate accurately the propagation of electrical signals in the heart. Combining a meshless solution for both the determination of the fibers and the electrical signal propagation can allow for solution that do not require the definition of a mesh. To our knowledge, this work is the first one to propose a meshless rule-based method for myocardial fiber arrangement determination.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.