Abstract

A MELCOR model of Fukushima Daiichi Unit 1 accident was developed. The model is based on publicly available information, and the MELCOR input file is published as Electronic Supplementary data with this paper. In order to reproduce the measured containment pressure, it was necessary to model a leak from the reactor coolant system. Recirculation pump seal leak, starting 5h after the earthquake, was assumed in this study. The reactor pressure vessel lower head was calculated to fail, and all fuel was discharged to the containment. Almost all of the radioactive noble gases and about 0.05% of the cesium inventory were released to the environment, according to this calculation. Calculated release rates from Units 1, 2, and 3 were compared with measured radiation dose rate in the plant area.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.