Abstract

A human vestibular system is a group of devices in the inner ear that govern the balancing movement of the head, in which the saccule is responsible for sensing gravity accelerations. Imitating the sensing principle and structure of the Sensory Hair (SH) cell in the saccule, a Bionic Sensory Hair (BSH) was developed, and 9 BSH arrays were arranged in the bionic macular at the bottom of the spherical shell to prepare a Bionic Saccule (BS). Based on the piezoelectric equation, the electromechanical theoretical models of the BSH cantilever and BS were deduced. They were subjected to impact oscillations using an exciter, and their output charges were analyzed to check their sensing ability. The results showed that BSH could sense its bending deflection, and the BS could sense its position change in the sagittal plane and in space. They exhibited a sensitivity of 1.6104 Pc s2/m and a fast response and similar sensing principles and low resonance frequency to those of the human saccule. The BS is expected to be used in the field of robotics and clinical disease diagnosis as a part of the artificial vestibular system in the future.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have