Abstract

We describe a low-cost simulation model for teaching core needle biopsy to surgical trainees in Low- and Middle-income countries (LMICs). Pre-session and post-session surveys showed that correct core sampling (ability to hit the beetroot) after training was 91.4% compared to 75.7% before demonstration and improved adequacy (68.5% before v. 85.7% after). This low-cost model using locally available products is designed to simulate a palpable breast lump and can easily be incorporated into surgical training in LMICs, where a palpable breast lump is the commonest presentation of breast cancer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.