Abstract

We have measured how a low concentration of nitrous oxide affected respiratory sensation and ventilation. Severe dyspnoea was induced in nine normal subjects by a combination of hypercapnia and inspiratory elastic load (50 cm H2O litre-1). Subjects were asked to rate their sensation of respiratory discomfort using a visual analogue scale (VAS) while breathing either 20% nitrous oxide or 20% nitrogen gas mixture. We compared the effects of each gas mixture on respiratory sensation and ventilation using steady-state values of ventilatory variables and VAS scores obtained before, during and after inhalation of each gas mixture. Inhalation of 20% nitrous oxide reduced the sensation of respiratory discomfort from a median VAS score of 6.5 (range 5.0-8.1) before inhalation to 3.6 (2.4-5.9) during inhalation (P < 0.05). There was no significant change in minute ventilation but tidal volume increased during inhalation of 20% nitrogen did not alter VAS scores or ventilatory variables. We found that a low concentration of nitrous oxide greatly alleviated the intensity of dyspnoea without changing respiratory load compensation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call