Abstract

Measure of the cross-sectional area (CSA) of biological specimens is a primary concern for many biomechanical tests. Different procedures are presented in literature but besides the fact that noncontact techniques are required during mechanical testing, most of these procedures lack accuracy or speed. Moreover, they often require a precise positioning of the specimen, which is not always feasible, and do not enable the measure of the same section during tension. The objective of this study was to design a noncontact, fast, and accurate device capable of acquiring CSA of specimens mounted on a testing machine. A system based on the horizontal linear displacement of two charge-coupled device reflectance laser devices next to the specimen, one for each side, was chosen. The whole measuring block is mounted on a vertical linear guide to allow following the measured zone during sample tension (or compression). The device was validated by measuring the CSA of metallic rods machined with geometrical shapes (circular, hexagonal, semicircular, and triangular) as well as an equine superficial digital flexor tendon (SDFT) in static condition. We also performed measurements during mechanical testing of three SDFTs, obtaining the CSA variations until tendon rupture. The system was revealed to be very fast with acquisition times in the order of 0.1 s and interacquisition time of about 1.5 s. Measurements of the geometrical shapes yielded mean errors lower than 1.4% (n=20 for each shape) while the tendon CSA at rest was 90.29 ± 1.69 mm(2) (n=20). As for the tendons that underwent tension, a mean of 60 measures were performed for each test, which lasted about 2 min until rupture (at 20 mm/min), finding CSA variations linear with stress (R(2)>0.85). The proposed device was revealed to be accurate and repeatable. It is easy to assemble and operate and capable of moving to follow a defined zone on the specimen during testing. The system does not need precise centering of the sample and can perform noncontact measures during mechanical testing; therefore, it can be used to measure variations of the specimen CSA during a tension (or compression) test in order to determine, for instance, the true stress and transverse deformations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.