A non-intrusive technique to measure the two-dimensional distribution of line averaged void fraction in a two-phase flow is discussed. A CCD camera is used to measure the attenuation of light as it passes through a bubbly flow, and this attenuation is related to the bubble concentration. The technique is appropriate for microbubbly flows where the bubble size is much smaller than the area imaged by a single pixel and where there are many bubbles attenuating light within each pixel. The measurement system is calibrated by using a two-dimensional line source microbubble plume as a reference.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.