Abstract

We present a non-invasive optical method based on infrared laser interferometry to study the thermal time constant in dielectrically isolated smart power devices. By analyzing the time domain optical reflectivity signal, the thermal time constant is determined independently of the applied heating power. Experimental values of the time constant are confirmed by calculations using equivalent thermal RC-networks.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.