Abstract
A muon telescope equipped with four multi-gap Resistive Plate Chambers of 2 m2 per plane was tested with the muon scattering tomography technique. The telescope was operated during several hours with high atomic number materials located at its center with two detector planes on each side. With an intrinsic efficiency above 98%, spatial resolution around 1 cm and detector planes spaced by 45 cm, it was possible to identify the presence of a 5 cm thick tungsten block in 10 min of acquisition. The results obtained after five hours of acquisition are also presented in this communication.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.